Product introduction
MHVS-1000 PLUS AOLONG CHIP Digital Auto Turret Micro Vickers Hardness Tester.
It is a high-tech product of optoelectronic integration. The instrument is novel and beautiful, and it has good reliability, operability and intuition. It is an upgraded product of microhardness tester.
The machine uses computer software programming, high-power optical measurement system, optical sensing technology, and through 8-inch color touch screen input, it can adjust the intensity of the measuring light source, hold time, storage and so on. It also provides various hardness conversion tables for reference. It can display test methods and tests on LCD large screen display screen. Force, indentation length, hardness value, holding time of test force, number of times of measurement can be typed in year, month, day, test result and data processing, etc., and output by printer.
The hardness tester can be equipped with a photographic device, which can photograph the indentation and metallographic structure of the material. It is suitable for measuring the microhardness of small, thin-shaped and surface-infiltrated coatings and brittle materials such as glass, ceramics, agate and gemstone. It is a research institution, enterprise and quality inspection department. The ideal hardness testing instrument.
Functional characteristics
8 test forces, selection range: 10gf-1Kgf u Optical system: electronic eyepiece The eyepiece has a 10X magnification. High quality objective lenses for maximum comfort Adjustable optical path Double Channel Optical System Measurement confirmation key, mounted in electronic eyepiece Hardness value of test, automatic calculation, automatic display Automatic and accurate positioning of test points The hardness conversion control can be selected according to different materials.
Technical parameters
Model |
MHVS-1000 PLUS |
|
Test force |
10gf、25gf、 50gf、100gf、200gf、300gf、500gf、1kgf |
|
0.098N、0.245N、0.49N、0.98N、1.96N、2.94N、4.9N、9.8N |
|
Loading mode |
Automatic(Loading、Duration、Uploading) |
|
Objective lens and indenter conversion |
Automatic |
|
Testing mode |
HV |
|
Measuring the magnification of a microscope |
100X(Observe) |
|
400X(Measure) |
|
Hardness test range |
5-3000HV |
|
Dwell time |
0-60s |
|
D1\D2 value input |
Automatic |
|
Hardness reading |
Large screen LCD reading |
|
Data output |
Built-in printer,RS232 interface |
|
|
Executive Standard |
ISO6507、ASTM E384、JIS Z2244、GB/T 4340 |
|
Scale conversion |
HRA、HRB、HRC、HR15N、HR30N、HR45N、HR15T、HR30T、HR45T、HK、HBW |
|
X-Y test-bed |
Size: 100×100mm、Route: 25×25mm、Resolution: 0.01mm |
Minimum Resolution |
0.1μm |
|
Maximum height of specimen |
100mm |
|
Maximum width of specimen |
100mm |
|
Power suuply |
AC220V+5%、50-60Hz |
|
Shape size |
520*320*560mm |
|
Machine net weight |
About 40kg |
|
Standard Configuration
Name |
Quantity |
Name |
Quantity |
Weight shaft |
1 |
Weights |
6 |
XY test-bed |
1 |
Slice clamping table |
1 |
Flat-mouthed clamping table |
1 |
Filament clamping table |
1 |
screwdriver |
2 |
Horizontal adjustment screw |
4 |
Power cord |
1 |
Vickers hardness block |
2 |
10X micrometer |
1 |
Manual book |
1 |
Level |
1 |
|
|
Product Qualification Certificate |
1 |
|
|
Optional Accessories
Vickers automatic measuring system |
HV-CCD |
Computert |
Mainstream configuration |
Printer |
Mainstream configuration |
Product introduction
MHVS-1000 PLUS AOLONG CHIP Digital Auto Turret Micro Vickers Hardness Tester.
It is a high-tech product of optoelectronic integration. The instrument is novel and beautiful, and it has good reliability, operability and intuition. It is an upgraded product of microhardness tester.
The machine uses computer software programming, high-power optical measurement system, optical sensing technology, and through 8-inch color touch screen input, it can adjust the intensity of the measuring light source, hold time, storage and so on. It also provides various hardness conversion tables for reference. It can display test methods and tests on LCD large screen display screen. Force, indentation length, hardness value, holding time of test force, number of times of measurement can be typed in year, month, day, test result and data processing, etc., and output by printer.
The hardness tester can be equipped with a photographic device, which can photograph the indentation and metallographic structure of the material. It is suitable for measuring the microhardness of small, thin-shaped and surface-infiltrated coatings and brittle materials such as glass, ceramics, agate and gemstone. It is a research institution, enterprise and quality inspection department. The ideal hardness testing instrument.
Functional characteristics
8 test forces, selection range: 10gf-1Kgf u Optical system: electronic eyepiece The eyepiece has a 10X magnification. High quality objective lenses for maximum comfort Adjustable optical path Double Channel Optical System Measurement confirmation key, mounted in electronic eyepiece Hardness value of test, automatic calculation, automatic display Automatic and accurate positioning of test points The hardness conversion control can be selected according to different materials.
Technical parameters
Model |
MHVS-1000 PLUS |
|
Test force |
10gf、25gf、 50gf、100gf、200gf、300gf、500gf、1kgf |
|
0.098N、0.245N、0.49N、0.98N、1.96N、2.94N、4.9N、9.8N |
|
Loading mode |
Automatic(Loading、Duration、Uploading) |
|
Objective lens and indenter conversion |
Automatic |
|
Testing mode |
HV |
|
Measuring the magnification of a microscope |
100X(Observe) |
|
400X(Measure) |
|
Hardness test range |
5-3000HV |
|
Dwell time |
0-60s |
|
D1\D2 value input |
Automatic |
|
Hardness reading |
Large screen LCD reading |
|
Data output |
Built-in printer,RS232 interface |
|
|
Executive Standard |
ISO6507、ASTM E384、JIS Z2244、GB/T 4340 |
|
Scale conversion |
HRA、HRB、HRC、HR15N、HR30N、HR45N、HR15T、HR30T、HR45T、HK、HBW |
|
X-Y test-bed |
Size: 100×100mm、Route: 25×25mm、Resolution: 0.01mm |
Minimum Resolution |
0.1μm |
|
Maximum height of specimen |
100mm |
|
Maximum width of specimen |
100mm |
|
Power suuply |
AC220V+5%、50-60Hz |
|
Shape size |
520*320*560mm |
|
Machine net weight |
About 40kg |
|
Standard Configuration
Name |
Quantity |
Name |
Quantity |
Weight shaft |
1 |
Weights |
6 |
XY test-bed |
1 |
Slice clamping table |
1 |
Flat-mouthed clamping table |
1 |
Filament clamping table |
1 |
screwdriver |
2 |
Horizontal adjustment screw |
4 |
Power cord |
1 |
Vickers hardness block |
2 |
10X micrometer |
1 |
Manual book |
1 |
Level |
1 |
|
|
Product Qualification Certificate |
1 |
|
|
Optional Accessories
Vickers automatic measuring system |
HV-CCD |
Computert |
Mainstream configuration |
Printer |
Mainstream configuration |
Product introduction
MHVS-1000 PLUS AOLONG CHIP Digital Auto Turret Micro Vickers Hardness Tester.
It is a high-tech product of optoelectronic integration. The instrument is novel and beautiful, and it has good reliability, operability and intuition. It is an upgraded product of microhardness tester.
The machine uses computer software programming, high-power optical measurement system, optical sensing technology, and through 8-inch color touch screen input, it can adjust the intensity of the measuring light source, hold time, storage and so on. It also provides various hardness conversion tables for reference. It can display test methods and tests on LCD large screen display screen. Force, indentation length, hardness value, holding time of test force, number of times of measurement can be typed in year, month, day, test result and data processing, etc., and output by printer.
The hardness tester can be equipped with a photographic device, which can photograph the indentation and metallographic structure of the material. It is suitable for measuring the microhardness of small, thin-shaped and surface-infiltrated coatings and brittle materials such as glass, ceramics, agate and gemstone. It is a research institution, enterprise and quality inspection department. The ideal hardness testing instrument.
Functional characteristics
8 test forces, selection range: 10gf-1Kgf u Optical system: electronic eyepiece The eyepiece has a 10X magnification. High quality objective lenses for maximum comfort Adjustable optical path Double Channel Optical System Measurement confirmation key, mounted in electronic eyepiece Hardness value of test, automatic calculation, automatic display Automatic and accurate positioning of test points The hardness conversion control can be selected according to different materials.
Technical parameters
Model |
MHVS-1000 PLUS |
|
Test force |
10gf、25gf、 50gf、100gf、200gf、300gf、500gf、1kgf |
|
0.098N、0.245N、0.49N、0.98N、1.96N、2.94N、4.9N、9.8N |
|
Loading mode |
Automatic(Loading、Duration、Uploading) |
|
Objective lens and indenter conversion |
Automatic |
|
Testing mode |
HV |
|
Measuring the magnification of a microscope |
100X(Observe) |
|
400X(Measure) |
|
Hardness test range |
5-3000HV |
|
Dwell time |
0-60s |
|
D1\D2 value input |
Automatic |
|
Hardness reading |
Large screen LCD reading |
|
Data output |
Built-in printer,RS232 interface |
|
|
Executive Standard |
ISO6507、ASTM E384、JIS Z2244、GB/T 4340 |
|
Scale conversion |
HRA、HRB、HRC、HR15N、HR30N、HR45N、HR15T、HR30T、HR45T、HK、HBW |
|
X-Y test-bed |
Size: 100×100mm、Route: 25×25mm、Resolution: 0.01mm |
Minimum Resolution |
0.1μm |
|
Maximum height of specimen |
100mm |
|
Maximum width of specimen |
100mm |
|
Power suuply |
AC220V+5%、50-60Hz |
|
Shape size |
520*320*560mm |
|
Machine net weight |
About 40kg |
|
Standard Configuration
Name |
Quantity |
Name |
Quantity |
Weight shaft |
1 |
Weights |
6 |
XY test-bed |
1 |
Slice clamping table |
1 |
Flat-mouthed clamping table |
1 |
Filament clamping table |
1 |
screwdriver |
2 |
Horizontal adjustment screw |
4 |
Power cord |
1 |
Vickers hardness block |
2 |
10X micrometer |
1 |
Manual book |
1 |
Level |
1 |
|
|
Product Qualification Certificate |
1 |
|
|
Optional Accessories
Vickers automatic measuring system |
HV-CCD |
Computert |
Mainstream configuration |
Printer |
Mainstream configuration |
Standard Configuration
Name |
Quantity |
Name |
Quantity |
Weight shaft |
1 |
Weights |
6 |
XY test-bed |
1 |
Slice clamping table |
1 |
Flat-mouthed clamping table |
1 |
Filament clamping table |
1 |
screwdriver |
2 |
Horizontal adjustment screw |
4 |
Power cord |
1 |
Vickers hardness block |
2 |
10X micrometer |
1 |
Manual book |
1 |
Level |
1 |
|
|
Product Qualification Certificate |
1 |
|
|
Optional Accessories
Vickers automatic measuring system |
HV-CCD |
Computert |
Mainstream configuration |
Printer |
Mainstream configuration |
|